Search results for "Contrast echocardiography"
showing 10 items of 10 documents
Comparison of Sulfur Hexafluoride Microbubble (SonoVue)-Enhanced Myocardial Contrast Echocardiography With Gated Single-Photon Emission Computed Tomo…
2013
Objectives The purpose of this study was to compare sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography (MCE) with single-photon emission computed tomography (SPECT) relative to coronary angiography (CA) for assessment of coronary artery disease (CAD). Background Small-scale studies have shown that myocardial perfusion assessed by SonoVue-enhanced MCE is a viable alternative to SPECT for CAD assessment. However, large multicenter studies are lacking. Methods Patients referred for myocardial ischemia testing at 34 centers underwent rest/vasodilator SonoVue-enhanced flash-replenishment MCE, standard Tc-99m-labeled electrocardiography-gated SPECT, and quanti…
Color superposition: a new modality for contrast echocardiography.
1987
To improve the estimation of endocardial borders in echocardiography, a technique has been developed to combine images from contrasted and noncontrasted echocardiograms of the same heart-phase using a color superposition mode. This method allows both experienced as well as less experienced examiners to define the endocardial borders more reproducibly and objectively. This is achieved by displaying tissue structures as gray level images while the ventricular cavity is marked selectively by the color display of the contrast material zone. Results of volume estimations of the left ventricle by different examiners using several imaging modes including color superposition display are presented.
Methods to investigate coronary microvascular function in clinical practice.
2012
A growing amount of data is increasingly showing the relevance of coronary microvascular dysfunction (CMVD) in several clinical contexts. This article reviews techniques and clinical investigations of the main noninvasive and invasive methods proposed to study coronary microcirculation and to identify CMVD in the presence of normal coronary arteries, also trying to provide indications for their application in clinical practice.
Analysis of myocardial perfusion or myocardial function for detection of regional myocardial abnormalities. An echocardiographic multicenter comparis…
2007
Background: Echocardiography based myocardial perfusion imaging and regional wall motion analysis are used for evaluation of coronary artery disease and regional myocardial abnormalities. Aim: This study sought to compare myocardial contrast echocardiography (MCE) and 2D echocardiography with regard to interobserver variability and detection of regional myocardial abnormalities. Methods: In 70 patients evenly distributed between three ejection fraction groups based on biplane cineventriculography (>55%, 35-55%, <35%), unenhanced and contrast enhanced 2D echocardiography and myocardial contrast echocardiography (MCE; SonoVue (R); Bracco) were performed. Regional watt motion and myocardial pe…
Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhan…
2013
Background: Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV)functional analyses inthe settingof two-dimensional (2D) echocardiography. Theneedfor contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography for the assessment of LV volumes and ejection fraction (EF). Methods: A multicenter, open-label study was conducted including 63 patients, using intrasubject comparisons to assess the agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography as well as…
Comparison of Two- and Three-Dimensional Unenhanced and Contrast-Enhanced Echocardiographies Versus Cineventriculography Versus Cardiac Magnetic Reso…
2013
Contrast enhancement has been shown to improve detection of regional wall motion abnormalities (RWMA) in 2-dimensional (2D) echocardiography. This study determined the use of contrast enhancement in the setting of 3-dimensional (3D) echocardiography for definition of left ventricular RWMA compared with 2D echocardiography, cineventriculography, and cardiac magnetic resonance (CMR). In 63 patients, unenhanced and contrast-enhanced (SonoVue; Bracco Imaging S.p.A., Milan, Italy) 2D and 3D echocardiographies, CMR, and cineventriculography were performed. Hypokinesia in ≥1 segment defined the presence of RWMA. Interreader agreement (IRA) between 2 blinded off-site readers on presence of RWMA was…
Analysis of high-frequency rotational angioplasty-induced echo contrast.
1991
During high-frequency rotational angioplasty (HFRA), myocardial contrast enhancement (echo contrast) was observed by means of two-dimensional echocardiography. In order to evaluate the echo contrast produced by HFRA, an in vitro experimental model was built using a cylinder with the HFRA catheter scanned in a water bath. The cylinder was filled with blood, mineral water, and distilled water. With a 2.5-MHz transducer, echograms were recorded and analyzed by video intensitometer, and the maximum intensity IUmax and persistence time P were calculated. Rotation frequencies of 20,000-200,000 rpm with 2.0--mm burrs and times of 10 s were tested. In another model, hyperbaric conditions for the sa…
Transesophageal contrast echocardiography is not always the gold standard method in the identification of a patent foramen ovale: A clinical case
2015
In the embryo, Eustachian valve is a crescent-shaped membrane extending from the lower margin of the inferior vena cava and the ostium of the coronary sinus into the right atrium toward fossa ovalis and tricuspid valve. At birth, after the functional closure of the foramen ovale, the Eustachian valve loses its function, reducing to an embryo remnant. According to growing evidence, a persistent Eustachian valve is a frequent finding in patients with a patent foramen ovale (PFO). By directing the blood from the inferior cava to the interatrial septum, it may prevent the spontaneous closure of PFO after birth and indirectly predispose to paradoxical embolism. Transesophageal contrast enhanced …
The use of contrast echocardiography: a matter of clinical judgement
2005
In their editorial, Buck and Erbel1 raise the important question in which settings application of contrast agents to an echocardiographic examination is appropriate. There is no doubt that the beauty of echocardiography relates to its ease of use. We should acknowledge that highest accuracy in the determination of left ventricular function is not necessary in most patients referred for an echocardiographic evaluation. Thus, contrast echocardiography will not be a technique to be used in all patients for mere evaluation of left ventricular function as cardiac magnetic resonance imaging will not be used in routine clinical practice only for its known superb accuracy. However, there are patien…
Assessment of systolic left ventricular function: a multi-centre comparison of cineventriculography, cardiac magnetic resonance imaging, unenhanced a…
2005
Aims To assess the agreement of left ventricular ejection fraction (LVEF) determinations from unenhanced echocardiography, contrast-enhanced echocardiography, magnetic resonance imaging (MRI), and cineventriculography as well as the inter-observer agreement for each method. Methods and results In 120 patients, with evenly distributed EF-groups (G 55, 35-55, L 35%), cineventriculography, unenhanced echocardiography with second harmonic imaging, and contrast echocardiography at tow mechanical index with iv administration of SonoVueR were performed. In addition, cardiac MRI at 1.5T using a steady-state free precession sequence was performed in a subset of 55 patients. On-site, and two blinded …